We strive to make our customers feel confident and proud when they use our products and services. When passing the device on to third parties, be sure to include this operating manual. Due to the cost of these useful instruments, youll have to take care to preserve their condition. In positive displacement pipetting, the piston is in direct contact with the liquid. L pipetman tips except filter tips may be auto dl10 0. Wait a few seconds after the plunger returns to its original position before moving the pipette. The device is used with accessories or consumables which are not recommended by eppendorf. The ultralight eppendorf research plus mechanical pipette not only meets the highest needs in precision and accuracy, it also provides you with increased flexibility and ultimate ergonomics. If you need pipette parts, tools or batteries for almost any pipette, we most likely have them.

Operating manual pipette supplies largest pipette parts. Using the biocompare pipettor search tool, you can access a wide variety of different pipettors, categorized by type, volume, volume format, channel format, channel number, and brand. Contamination caused by ingress of liquid must be removed. Pipettes with a friction seal system, rely on a users force to attach tips to the pipette, which varies from user to user. Manual multi channel pipettes multichannel pipettes are useful in a variety of applications, the multichannel pipette improves laboratory efficiency by speeding up throughput. B biopur eppendorf biopur is an eppendorf ag purity level for consumables. The device is not used in accordance with the operating manual. Product description eppendorf research plus english en 6 1. The new, ergonomic design of the pipettors allow for consistently comfortable pipetting even with extended use. When the tip is immersed, use the plunger button to allow the plunger to return to its starting position fully extended.

Buy the manual repeating pipette and get a free unit of nonsterile repeating tips. To ensure safe, problemfree service from the reference pipette, it is essential to observe the following points. With the devices only able to contain certain volumes, the delivered quantities are more consistent which yields highly reproducible results even after many uses. There are different ways do disinfect your manual pipette. Eppendorf repeater m4 manual handheld pipette dispenser. We understand every lab is unique and will work with you to develop a seamless and integrated online procurement strategy. Eppendorf knows calibration and knows how to do it right. In air displacement pipettes, a certain volume of air remains between the piston and the liquid. Eppendorf research plus liquid handling starter 1 package, singlechannel, includes 4 singlechannel adjustable volume research plus pipettes 0. Eppendorf milestones 1945 present eppendorf corporate. It is not affected by liquid properties, most manual pipetting errors and provides protection from aerosol contamination. Please view this operating manual as part of the product and keep it somewhere easily accessible. How to order there are several ways to order your eppendorf product.

The unique onebutton operation offers fast and ergonomic handling with reduced operating effort and active aerosol reductionserving as a media dispenser, the pipettors are commonly used to transport specific liquid volumes. Eppendorf pipette reference 2 user manual 44 pages. Eppendorf reference 2 liquid handling starter 1 package, singlechannel, variable, includes 4 singlechannel adjustable volume reference 2 pipettes 0. Before using the reference pipette, please read the operating manual. The combitips advanced are made to complete the system. Hermetically sealed they offer a high level of safety for handling of infectious, toxic. Eppendorf research plus operating manual 10 3 operation 3. Keeping a pipette clean, calibrated and serviced guarantees a long lifetime and accurate results. Rainin offers stateoftheart single channel, multichannel and adjustable spacer manual pipettes and accessories that raise the bar on comfort, performance and control.

M4 manual handheld pipette dispenser dispenses liquid directly without air cushion, ensuring correct volume is dispensed regardless of density, viscosity and. Effective use of the multichannel requires additional care to seat tips correctly and achieve uniform accuracy in each tip. Eppendorf north america products manual liquid handling. Both pipette types have a piston that moves in a cylinder or capillary. The pipette operates according to the air cushion principle. Aggressive substances can damage the pipette, pipette tips and. Increased tip attachment and ejection forces loose tips which can drop off or leak air. The multipettecombitips system builds the perfect harmony allowing automatic tip recognition for ease of use. How to clean a pipette correctly eppendorf handling solutions. Depending on the research plus pipette it is possible to dispense volumes from 0. The builtin safety features of varispenser 2 and varispenser 2x protect the user from accidental spills and ensure smooth, troublefree dispenser operation.

Eppendorf reference 2 6pack organized, variable, 6 singlechannel, variable eppendorf reference 2 pipettes 0. How to clean a pipette correctly eppendorf handling. Eppendorf reference read online or download pdf eppendorf pipette reference 2 user manual manuals directory online owner manuals library search. Uses positive displacement principal to precisely and accurately dispense virtually any liquid. Single channel pipettes thermo fisher scientific us. For use with a wide range of compatible liquids including corrosive and inflammable liquids, liquids of high viscosity, detergent solutions, foaming liquids or liquids with high vapor pressure or density. Pipette model tips model range color code a lack of precision. A history of over 50 years in liquid handling has resulted in awardwinning designs, cuttingedge production, optimal materials selection and.

Pipettes are used on a daily basis and are often the most important tools in the laboratory. Eppendorf top buret m, 25 ml, singlechannel, manual, bottletop buret with safety valve, telescopic aspiration tube, variable discharge tube, for 45 mm bottle thread, incl. Even viscous or volatile liquids that are difficult to pipette are no match for the multipette m4. The autorep e electronic and autorep s manual are precise, accurate repeater pipettes that save time, with ergonomic features that reduce user fatigue. User name password forgot my password new customer, register now. Eppendorf pipettes are a common laboratory tool used to measure and transport liquid. You can do most maintenance by yourself in the lab. User manuals instructions for gilson, rainin, eppendorf, sartorius, finnpipette, and many more pipette brands are available here for your convenience. Eppendorf reference 2 english en 5 1 operating instructions 1. Pipette performance can only be guaranteed a performance da pipeta somente pode ser if highquality pipette tips are used. The eppendorf multipette m4 is the ideal precision instrument for completing long pipetting series.

Flexible volume ranges and a wide selection of quickchange positivedisplacement syringe tips ensure. When the control button is pressed, the piston in the pipette moves in the same direction. Eppendorf reference read online or download pdf eppendorf pipette reference 2 user manual. With the new 16 and 24channel pipette system for 384well plates eppendorf has surpassed itself again by combining proven concepts with new innovations. Since its founding eppendorf is known as a premium brand. Perfection lies in the details this a principle that definitely holds true for our handheld pipettes and associated consumables. This pipette is an in vitro diagnostic device according to directive 9879ec of the european. Pipettes and pipetting aspirating the liquid steps dispensing the liquid step 4. The repetitive dispensing modes contribute to reducing fatigue by decreasing the number of movements for the user. Eppendorf research plus operating manual 1 product description 1 1.

The device is maintained or repaired by individuals not authorized by eppendorf. For air cushion pipettes, a suitable pipette tip must be fitted prior to use. Serving as a media dispenser, the pipettors are commonly used to transport specific liquid volumes. The eppendorf liquid handling instrument portfolio as the inventor of the microliter system, we at eppendorf have over fifty years of experience in precise manual and automatic pipettingdispensing and transferring of the smallest quantities of liquids. Please also note the operating instructions for the accessories, if applicable. A suitable pipette tip must be fitted prior to use. The user controls the dispensing, volume setting and ejector using the control button. Vwr signature ergonomic high performance singlechannel. The dispensing and volume setting ring are controlled with the dispensing. Today, the contribution of over 3,600 employees in over 26 countries helps to ensure that eppendorf is recognized as expert partner in life science laboratories worldwide. The syringe style combitips tip maximizes pipetting accuracy and precision. Eppendorf research plus 6pack organized, 6 singlechannel variable volume eppendorf research plus pipettes 0. Eppendorf repeater m4 manual handheld pipette dispenser dispenses liquid directly without air cushion, ensuring correct volume is dispensed regardless of density, viscosity and volatility of liquid. Searching for the right pipette or pipettor does not have to as complicated as troubleshooting an experiment.